13.07.2015 Views

P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

User Guide<strong>P12x</strong>/<strong>EN</strong> FT/<strong>Eb6</strong>MiCOM P120/P121/P122/P123 Page 41/62NOTE:To reset the latched output relay:P120 P121 P122 &P123To reset the latched relayswith MiCOM P120:When a relay associated to atime delay overcurrentthreshold is latched, nodedicated alarm signallingthat the relay has beenlatched is displayed.The latched output can bereset by acknowledging thealarm message pressing keys and .The latched relay can also bereset either by an opto inputor by a remote command.2.9.3 Submenu Blocking LogicThe active relay latched canbe reset by:- Either by resetting of thealarm "tI> PHASE"* fromthe front panel by pushing.- or by a logic input assignedto this function- or by remote command.Note: No alarm dedicated tothe latch of RL1The active relay latched canbe reset by:- Either by resetting of thealarm "LATCH RELAYTRIP" from the front panelby pushing .- or by a logic input assignedto this function- or by remote command.Note: The alarm "LATCHRELAY TRIP" is dedicated tothe latch of RL1*: tI> or other function presented in the "AUTOMAT. CTRL/Latch functions" menuThrough the Blocking Logic submenu, the user can block each delayed threshold using a "BlockLogic" input (refer to Inputs menu). MiCOM P122 & P123 relays have the submenu BlockingLogic 1 and Blocking Logic 2 available for setting.It is possible to enable or disable the “blocking” of most protection functions even if a logicinput has been assigned to that function.Function P120 P121 P122 P123 INFORMATION and COMM<strong>EN</strong>TStI> X X X X Time delayed first phase overcurrentthresholdtI>> X X X X Time delayed second phase overcurrentthresholdtI>>> X X X X Time delayed third phase overcurrentthresholdtIe> X X X X Time delayed first earth overcurrent thresholdtIe>> X X X X Time delayed second earth overcurrentthresholdtIe>>> X X X X Time delayed third earth overcurrentthresholdtIe>>>> X X Time delayed of derived earth overcurrentthreshold.tI2 > X X Time delayed first negative phase sequenceovercurrent thresholdtI2 >> X X Time delayed second negative phasesequence overcurrent threshold.Thermal θ X X Trip threshold for thermal overload.Brkn.Cond X X Broken Conductor trip signal.tAux 1 X X X Aux1 Logic Input delayed by Aux1 timetAux 2 X X X Aux2 Logic Input delayed by Aux2 timetAux 3 X X Aux3 Logic Input delayed by Aux3 timetAux 4 X Aux4 Logic Input delayed by Aux4 timetAux 5 X Aux5 Logic Input delayed by Aux5 time

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!