13.07.2015 Views

P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Commissioning and Maintenance<strong>P12x</strong>/<strong>EN</strong> CM/<strong>Eb6</strong>MiCOM P120/P121/P122/P123 Page 5/183. PRODUCT VERIFICATION TESTSBEFORE CARRYING OUT ANY WORK ON THE EQUIPM<strong>EN</strong>T, THEUSER SHOULD BE FAMILIAR WITH THE CONT<strong>EN</strong>TS OF THE SAFETYGUIDE SFTY/4LM/E11 OR LATER ISSUE, OR THE SAFETY ANDTECHNICAL DATA SECTIONS OF THE TECHNICAL MANUAL ANDALSO THE RATINGS ON THE EQUIPM<strong>EN</strong>T RATING LABEL.3.1 Allocation of terminalsIt is necessary to consult the appropriate wiring diagram provided in the APP<strong>EN</strong>DIX 1 of theTechnical Guide whilst observing the various polarities and ground/earth connection.3.2 Electrostatic discharge (ESD)Before any handling of the module (active part of the relay), please refer to therecommendations in User guide of this Technical Guide.3.3 Visual inspectionCarefully examine the relay to see if there has been any possible deterioration followinginstallation.Check if the external wiring corresponds to the appropriate relay diagram or the assemblydiagram. The reference number of the relay diagram is indicated on a label situated underthe upper flap of the front panel.When the relay is withdraw from its case, use a continuity tester to check if the current shortcircuits(phases and earth CT's) between the terminals indicated on the wiring diagram areclosed.3.4 EarthingCheck if the earth connection of the case situated above the rear terminal block is used toconnect the relay to a local earth bar. With several relays present, make sure that the copperearth bar is properly installed for solidly connecting the earthing terminals of each case.3.5 Current transformers (CT's)WARNING:NEVER OP<strong>EN</strong> CIRCUIT THE SECONDARY CIRCUIT OF A CURR<strong>EN</strong>TTRANSFORMER SINCE THE HIGH VOLTAGE PRODUCED MAY BELETHAL AND COULD DAMAGE INSULATION.3.6 Use of a Core CT for earth faults.If a core CT is used to detect earth faults, prior to any test, the user must check the followingpoints:MV or HV cable screens and core CT,No current flow through the MV or HV cables,Orientation of the core CT (P1-S1, P2-S2)3.6.1 Cable shields and core CTWhen mounting a core CT around electric cables, check the connection to the earth of thecable shields. It is vital that the earth cable of the shield moves in the opposite directionthrough the core CT. This cancel the currents carried by the cable shields through the coreCT.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!