176 <strong>AFI</strong><strong>11</strong>-<strong>2C</strong>-130V3 23 APRIL 2012<br />

12.10.3.3.4. Reconnect the INS Battery connector<br />

12.10.3.3.5. Check the DC voltmeter in the ESS DC BUS position to verify the bus is<br />

powered.<br />

12.10.3.3.5.1. If the ESS DC BUS is not powered, bypass the relay as follows:<br />

12.10.3.3.5.1.1. Remove all power from the aircraft.<br />

12.10.3.3.5.1.2. Disconnect the INS battery.<br />

12.10.3.3.5.1.3. Bypass the INS RCR by installing a #4 jumper wire from the<br />

GEN terminal to the BAT terminal of the reverse current relay. (See Figure<br />

12.<strong>11</strong>)<br />

12.10.3.3.5.1.4. Connect the INS battery.<br />

12.10.3.3.6. Start GTC/APU. WARNING: Fire protection is not available for the<br />

GTC/APU, until the Battery Relay is jumped.<br />

12.10.3.3.6.1. Place Bleed Air Valve switch to OPEN (airplanes with ATM).<br />

12.10.3.3.7. Place ATM and generator/APU generator switch to ON. Check Voltage<br />

and Frequency.<br />

12.10.3.3.8. Remove #10 jumper wire from the INS RCR.<br />

12.10.3.3.9. Jump the battery relay using Failed Battery Relay procedure. (See<br />

paragraph 12.10.3.5) WARNING: If the INS RCR has been bypassed by<br />

installing the #4 jumper wire, neither the ISOLATED DC bus nor the ESSENTIAL<br />

DC bus can be isolated using bus isolation procedures in the flight manual.<br />

12.10.3.4. Failed RCR between Isolated and Essential DC Bus. WARNING: When<br />

performing maintenance inside any circuit breaker panel all aircraft power must be<br />

removed to prevent injury to personnel or equipment.<br />

12.10.3.4.1. Remove External Power and disconnect both the Aircraft and INS/SCNS<br />

batteries.<br />

12.10.3.4.2. Open pilot‘s side circuit breaker panel.<br />

12.10.3.4.3. Install a #10 jumper wire between the SW post and the APP post (see<br />

Figure 12.2).<br />

12.10.3.4.4. If the RCR fails to energize, bypass the relay as follows:<br />

12.10.3.4.4.1. Remove all power from the aircraft.<br />

12.10.3.4.4.2. Disconnect the aircraft battery.<br />

12.10.3.4.4.3. Install a #4 jumper wire between the BATT and GEN terminals<br />

(see Figure 12.2).<br />

12.10.3.4.4.4. Connect the aircraft battery. WARNING: The Essential DC bus<br />

cannot be isolated using bus isolation procedures contained in the flight manual.<br />

NOTE: When the #4 jumper wire is used on the RCR, the Iso DC on Batt/Batt<br />

Disc light will remain ON, even though the Essential DC bus is powering the<br />

Isolated Bus.