Under development<br />

• Baud rate calculation for an external clock input:<br />

1) UART mode<br />

<strong>TMPM330</strong> (rev 0.4) 9-12<br />

<strong>TMPM330</strong><br />

Baud Rate = external clock input / 16<br />

In this, the period of the external clock input must be equal to or greater than 2/fsys.<br />

If fsys = 32 MHz, the highest baud rate will be 32÷2÷16=1.0 (Mbps).<br />

2) I/O interface mode<br />

Baud Rate = external clock input<br />

When double buffering is used, it is necessary to satisfy the following relationship:<br />

External clock input period > 6/fsys<br />

Therefore, when fsys = 32 MHz, the baud rate must be set to a rate lower than<br />

32÷6=5.33 (Mbps).<br />

When double buffering is not used, it is necessary to satisfy the following relationship:<br />

External clock input period > 8/fsys<br />

Therefore, when fsys = 32 MHz, the baud rate must be set to a rate lower than<br />

32÷8=4.0 (Mbps).<br />

The baud rate examples for the UART mode are shown in Table 9-4 and Table 9-5.<br />