ADMOD3<br />

Under development<br />

A/D Mode Control Register 3<br />

<strong>TMPM330</strong> (rev 0.4)13 -6<br />

<strong>TMPM330</strong><br />

7 6 5 4 3 2 1 0<br />

Bit symbol ADOBIC REGS3 REGS2 REGS1 REGS0 ADOBSV<br />

Read/Write R/W R R/W<br />

After reset 0 0 0 0 0 0 0 0<br />

Function<br />

Write “0”. “0” can be<br />

read.<br />

Make AD<br />

monitor<br />

function<br />

interrupt<br />

setting<br />

0: Smaller<br />

than<br />

comparison<br />

Reg.<br />

1: Larger than<br />

comparison<br />

Reg.<br />

<br />

AD conversion<br />

result storage Reg.<br />

to be compared<br />

0000 ADREG08<br />

0001 ADREG19<br />

0010 ADREG2A<br />

0011 ADREG3B<br />

0100 ADREG4C<br />

0101 ADREG5D<br />

0110 ADREG6E<br />

0111 ADREG7F<br />

1XXX ADREGSP<br />

BIT for selecting the AD conversion result storage Reg. that is to<br />

be compared with the comparison Reg. if the AD monitor<br />

function is enabled<br />

Fig. 13-5 A/D Mode Control Register 3<br />

AD monitor<br />

function<br />

0:Disable<br />

1:Enable<br />