Under development<br />

8.2.1.1 TMRBn enable register (channels 0 through 9)<br />

TBnEN<br />

(0x4001_0xx0)<br />

bit Symbol<br />

TMRBn enable register (n=0~9)<br />

31 30 29 28 27 26 25 24<br />

Read/Write R R R R R R R R<br />

After reset 0 0 0 0 0 0 0 0<br />

bit Symbol<br />

23 22 21 20 19 18 17 16<br />

Read/Write R R R R R R R R<br />

After reset 0 0 0 0 0 0 0 0<br />

bit Symbol<br />

15 14 13 12 11 10 9 8<br />

Read/Write R R R R R R R R<br />

After reset 0 0 0 0 0 0 0 0<br />

7 6 5 4 3 2 1 0<br />

bit Symbol TBnEN<br />

Read/Write R/W R<br />

After reset 0 0<br />

Function<br />

TMRBn<br />

operation<br />

0:<br />

Disabled<br />

1:<br />

Enabled<br />

“0” is read.<br />

<strong>TMPM330</strong> (rev 0.4)8-8<br />

<strong>TMPM330</strong><br />

: Specifies the TMRB operation. When the operation is disabled, no clock is supplied to the other<br />

registers in the TMRB module. This can reduce power consumption. (This disables reading<br />

from and writing to the other registers.) To use the TMRB, enable the TMRB operation (set to<br />

“1”) before programming each register in the TMRB module. If the TMRB operation is executed<br />

and then disabled, the settings will be maintained in each register.<br />

16-bit Timer/<br />

Event Counters (TMRBs)