15.5 Operational description<br />

(1) Reading clock data<br />

1. Using 1Hz interrupt<br />

Under development<br />

<strong>TMPM330</strong> (rev0.4) 15-10<br />

<strong>TMPM330</strong><br />

The count-up of the internal data synchronizes with 1Hz interrupt. Data can be read<br />

correctly if reading data after 1Hz interrupt occurred.<br />

2. Using pair reading<br />

There is a possibility that the clock data may be read incorrectly if the internal counter<br />

operates carry during reading. To ensure correct data reading, read the clock data twice<br />

as shown below. A pair of data read successively needs to match.<br />

Start<br />

PAGER = “0”, then<br />

select PAGE0<br />

Clock data reading<br />

(1st)<br />

Clock data reading<br />

(2nd)<br />

1 st data = 2 nd data<br />

End<br />

YES<br />

NO<br />

Fig. 15-2 Flowchart of the clock data reading<br />

Real Time Clock