Under development<br />

11.2.6 Receive Enable Register [CECREN]<br />

<strong>TMPM330</strong> (rev0.4)11-5<br />

<strong>TMPM330</strong><br />

7 6 5 4 3 2 1 0<br />

bit Symbol ― CECREN<br />

Read/Write R R/W<br />

After reset 0 0<br />

Function<br />

“0” is read. Receptio<br />

n control<br />

[Write]<br />

0:<br />

Disabled<br />

1:<br />

Enabled<br />

[Read]<br />

0:<br />

Stopped<br />

1: in<br />

operation<br />

: Controls the reception operation of CEC.<br />

Writing “0” or “1” to this bit enables or disables data reception. This bit becomes ready<br />

for data reception by writing “1”.<br />

The state of the reception circuit is monitored by reading this bit. It enables you to<br />

check if what you set has properly been reflected.<br />

(Note 1) Enable the bit after setting the reception control register 1, 2 and 3.<br />

(Note 2) It takes a little time to reflect the setting of the bit to the circuit. Stop<br />