SBIxCR1<br />

Under development<br />

Serial bus control register 1<br />

7 6 5 4 3 2 1 0<br />

Bit symbol BC2 BC1 BC0 ACK SCK2 SCK1<br />

<strong>TMPM330</strong> (rev 0.4) 10-6<br />

<strong>TMPM330</strong><br />

SCK0/<br />

SWRMON<br />

Read/Write R/W R/W R R/W R/W<br />

After reset 0 0 0 0 1 0 0 1<br />

Function Select the number of bits per Acknowled<br />

gment<br />

transfer (Note 1)<br />

clock<br />

0: Not<br />

generate<br />

1: Generate<br />

This can<br />

be read as<br />

“1.”<br />

Select internal SCL output clock<br />

frequency (Note 2) and reset monitor.<br />

15 14 13 12 11 10 9 8<br />

Bit symbol<br />

Read/Write R<br />

After reset 0<br />

Function This can be read as “0.”<br />

23 22 21 20 19 18 17 16<br />

Bit symbol<br />

Read/Write R<br />

After reset 0<br />

Function This can be read as “0.”<br />

31 30 29 28 27 26 25 24<br />

Bit symbol<br />

Read/Write R<br />

After reset 0<br />

Function This can be read as “0.”<br />

: Select internal SCL output clock frequency<br />

< SWRMON:0>: Software reset status monitor<br />

: Select the number of bits per transfer<br />

Fig. 10-4 I 2 C Bus Mode register<br />

On writing : Select internal SCL output clock<br />

frequency<br />

000 n=5 196 kHz<br />

001 n=6 149 kHz System clock: fsys<br />

010 n=7 101 kHz<br />

(=40 MHz)<br />

011 n=8 61 kHz Clock gear : fc/1<br />

100<br />

101<br />

110<br />

n=9<br />

n=10<br />

n=11<br />

34<br />

18<br />

9<br />

kHz<br />

kHz<br />

kHz<br />

fsys/2<br />

Frequency = [ Hz ]<br />

2<br />

111 reserved<br />

n +70<br />

On reading : Software reset status monitor<br />

0 Software reset operation is in progress.<br />

1 Software reset operation is not in progress.<br />

Select the number of bits per transfer<br />

When = 0 When = 1<br />

Number of Data Number of Data<br />

clock cycles length clock cycles length<br />

000 8<br />

8 9<br />

8<br />

001 1<br />

1 2<br />

1<br />

010 2<br />

2 3<br />

2<br />

011 3<br />

3 4<br />

3<br />

100 4<br />

4 5<br />

4<br />

101 5<br />

5 6<br />

5<br />

110 6<br />

6 7<br />

6<br />

111 7<br />

7 8<br />

7<br />

Serial Bus Interface (SBI)