Device;<br />

(2) ANSI A92.2-1979, Vehicle-Mounted Elevating and Rotating Aerial<br />

(3) ANSI A92.3-1980, Manually Propelled Elevating Work Platforms;<br />

(4) ANSI A92.5-1980, Boom-Supported Elevating Work Platforms;<br />

(5) ANSI A92.6-1979, Self-Propelled Elevating Work Platforms;<br />

(6) ANSI A92.7-1981, Airline Ground Support Vehicle-Mounted Vertical<br />

Lift Devices;<br />

(7) ASME/ANSI B30.22-1987, Articulating Boom Cranes (Commercial<br />

Truck-Mounted);<br />

(8) NFPA 1914-1988, Testing Fire Department Aerial Devices (Ladder<br />

Trucks/Platforms);<br />

(9) <strong>NAVFAC</strong> P-307, Maintenance and Certification <strong>of</strong> WHE.<br />

4-1.11.6 Inspection and Testing <strong>of</strong> Fire Department Aerial Devices<br />

a. General. All fire department aerial devices shall be inspected and tested<br />

in accordance with the current edition <strong>of</strong> the National Fire Protection Association<br />

(NFPA) 1914 Standard for "Testing Fire Department Aerial Devices." The NFPA 1914<br />

specifies minimum inspection and testing requirements and shall be used to<br />

supplement, not to replace or modify, any instructions recommended by the aerial<br />

device manufacturer. Aerial devices shall include fire apparatus equipped with aerial<br />

ladders, elevating platforms, and water towers designed to position personnel, handle<br />

materials and/or discharge water as specified in NFPA 1901, Standard on Automotive<br />

Fire Apparatus.<br />

b. Scope. Visual inspections, operational tests, and load tests specified in<br />

NFPA 1914 shall be conducted at least annually; after major repairs or overhaul; when<br />

the aerial device may have been subjected to unusual operating conditions <strong>of</strong> stress or<br />

load; or when there is reason to believe that usage has exceeded the manufacturer’s<br />

recommended operating procedures or capacity limits.<br />

(1) Inspection Personnel. Most <strong>of</strong> the inspections and tests outlined in<br />

NFPA 1914 are intended to be performed by "qualified" fire department personnel.<br />

"Qualified" is defined as a person who, by possession <strong>of</strong> a recognized degree,<br />

certificate, pr<strong>of</strong>essional standing, skill, knowledge, training and experience has<br />

demonstrated the ability to deal with problems relating to the subject matter, the work,<br />

or the project. However, if the fire department prefers, the inspections and tests can be<br />

performed by a third-party testing company or the manufacturer.<br />