1.1.3 Encoder monitoring<br />

HEIDENHAIN contouring controls can monitor the signal transmissions of the measuring system.<br />

This measuring system monitoring must be activated by a machine parameter.<br />

Three different conditions can be checked:<br />

Error message<br />

The absolute position of distance-coded reference marks C<br />

The amplitude of the measuring system signals A<br />

The edge separation of the measuring system signals B<br />

If one of the conditions is not fulfilled, it results in the error message:<br />

"Measuring system defect A/B/C."<br />

For sinusoidal signals the LE monitors the amplitude of the measuring system signals, for squarewave<br />

signals the LE evaluates the fault detection signal (U aS) of the external electronics (EXE or<br />

IBV).<br />

MP30 Checking the absolute position of the distance-coded reference marks<br />

Input range: 0 to 15<br />

Bit 0 X axis +0 = not active<br />

+1 = active<br />

Bit 1 Y axis +0 = not active<br />

+2 = active<br />

Bit 2 Z axis +0 = not active<br />

+4 = active<br />

Bit 3 4th axis +0 = not active<br />

+8 = active<br />

MP31 Checking the amplitude of the measuring system signals<br />

Input range: 0 to 31<br />

Bit 0 X axis +0 = not active<br />

+1 = active<br />

Bit 1 Y axis +0 = not active<br />

+2 = active<br />

Bit 2 Z axis +0 = not active<br />

+4 = active<br />

Bit 3 4th axis +0 = not active<br />

+8 = active<br />

Bit 4 Axis S +0 = not active<br />

+16 = active<br />

4-8 <strong>TNC</strong> <strong>360</strong> 1 Machine Axes 8/95