MP912 Traverse range 3: Maximum value<br />

MP922 Traverse range 3: Minimum value<br />

Activated by PLC: M2817 = 1, M2816 = 0<br />

MP912.0 Software limit switch X+<br />

MP912.1 Software limit switch Y+<br />

MP912.2 Software limit switch Z+<br />

MP912.3 Software limit switch 4+<br />

MP922.0 Software limit switch X–<br />

MP922.1 Software limit switch Y–<br />

MP922.2 Software limit switch Z–<br />

MP922.3 Software limit switch 4–<br />

The markers M2816 and M2817 are used to define the traverse range.<br />

M2816 M2817 Traverse range<br />

0 0 Range 1 (MP910.x; MP920.x)<br />

1 0 Range 2 (MP911.x; MP921.x)<br />

0 1 Range 3 (MP912.x; MP922.x)<br />

The change-over to the selected traverse range must be activated by the strobe marker M2824 by<br />

the PLC. This strobe marker is reset by the NC after the change-over has been carried out.<br />

In the "<strong>Manual</strong>" and "Electronic handwheel" modes of operation this is done immediately, in all other<br />

modes of operation it is usually done with the next M/S/T strobe. The range must be switched<br />

during an M/S/T strobes.<br />

Example:<br />

M2045<br />

M2482<br />

M2824<br />

In the <strong>Manual</strong> and Electronic Handwheel modes, the range can be switched immediately.<br />

Set Reset<br />

M2824 Activation of the selected traverse range PLC NC<br />

(M2816/M2817)<br />

If one of the software limit switches is reached, the error message "LIMIT SWITCH ..." appears and<br />

the appropriate marker (M2624 to M2631) is set.<br />

4-16 <strong>TNC</strong> <strong>360</strong> 1 Machine Axes 8/95