16.3.4 Testing the direction of traverse<br />

Test the controls for the direction of traverse according to the following diagram (effective machine<br />

parameters: MP210 count direction of the measuring system signals, MP1040 polarity of the<br />

nominal value voltage, MP1320 direction of traverse on passing over the reference marks).<br />

No<br />

Change<br />

MP210<br />

MP1040<br />

MP1320<br />

Yes<br />

Yes<br />

Reference traverse with<br />

machine START button<br />

Traverse<br />

direction correct?<br />

(as defined<br />

in MP1320)<br />

Test the traverse direction of<br />

referencing in each axis<br />

No<br />

START<br />

Line voltage on<br />

"Cross positioning error"<br />

or incorrect<br />

traverse direction<br />

after passing over<br />

ref. marks?<br />

4-232 <strong>TNC</strong> <strong>360</strong> 16 Commissioning and Start-up Procedure 8/95<br />

No<br />

Erase POWER INTERRUPTED error message with CE<br />

Control voltage on;<br />

axes are in the control loop<br />

Gross<br />

positioning error<br />

(MP1040 or<br />

MP210 incorrect)<br />

?<br />

No<br />

Start reference<br />

traverse with<br />

axis direction keys<br />

?<br />

Yes<br />

Axis traverse<br />

direction correct?<br />

(defined in MP1040<br />

and MP210)<br />

Test the traverse direction<br />

in each axis<br />

This flow diagram must be worked through for every axis!<br />

No<br />

Yes<br />

Line<br />

voltage<br />

off<br />

(Both types of<br />

referencing must<br />

be performed!)