3.5.3 Monitoring the analog voltage<br />

Monitoring of the analog voltage is only possible in operation with feed forward control.<br />

If it exceeds 10 V, the flashing error message<br />

is displayed.<br />

"Gross positioning error B"<br />

3.5.4 Movement monitoring<br />

The movement monitoring functions in operation with feed forward control as well as with lag.<br />

During movement monitoring, the actual path traveled is compared with a nominal path calculated<br />

by the NC at short intervals (several servo cycles). If, during this period, the actual path traveled<br />

differs from the calculated path, the flashing error message<br />

is displayed.<br />

"Gross positioning error C"<br />

In machine parameter MP1140 a voltage can be stored, below which the movement monitoring is<br />

out of action.<br />

If 10 [V] is entered in this machine parameter, the movement monitoring becomes<br />

inactive. It is not possible to operate the machine safely without movement<br />

monitoring.<br />

MP1140 Movement monitoring<br />

Input value: 0.03 to 10 [V]<br />

8/95 <strong>TNC</strong> <strong>360</strong> 3 Servo Positioning of the NC Axes 4-71