Calculation of Possible Oscillations in Normal Direction<br />

MP 6210 [1/s] = optimised F 1) [mm/min]<br />

PP.INT 2) [mm] x 60 [s/min]<br />

When the calculated machine parameter MP 6210 is entered the feed override potentiometer is<br />

trimmed to the "attained feed rate".<br />

1) Maximum possible feed rate noted during optimizing<br />

2) PP.INT is the programmed maximum probe point interval from the "Meander" scanning<br />

cycle (in the example, PP.INT = 1 mm).<br />

4-164 <strong>TNC</strong> <strong>360</strong> 9 Touch Probe 8/95