16.3.9 Adjust the offset<br />

The rough offset adjustment has already been carried out on the servo amplifier. A fine offset<br />

adjustment can be performed with the offset adjustment possibility described in Section "Servo<br />

positioning".<br />

16.3.10 Adjustment of the monitoring functions<br />

The following entry values are recommended for the monitoring functions (see Section "Servo<br />

positioning"):<br />

Machine parameter Function Entry value<br />

MP1710 Position monitoring 1.2 × lag in rapid traverse<br />

MP1720 Position monitoring (EMERGENCY STOP) 1.4 × lag in rapid traverse<br />

MP1410 Position monitoring 0.5 [mm]<br />

MP1420 Position monitoring (EMERGENCY STOP) 10 [mm]<br />

MP1140 Movement monitoring 0.5 [V]<br />

MP1030 Positioning window 0.01 [mm]<br />

MP1110 Standstill monitoring 0.2 [mm]<br />

If the drives of the machine permit narrower limits, these may be entered.<br />