06.08.2013 Views

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Rapid traverse<br />

[m/min]<br />

10<br />

8<br />

6<br />

4<br />

2<br />

kv = 2<br />

kv = 1<br />

2 4 6 8 10<br />

kv = 0.5<br />

s a [mm]<br />

The rapid traverse value stored in machine parameter MP1010 can be reduced by the PLC.<br />

The rapid traverse (maximum traversing speed) must be adjusted by the desired analog voltage (e.g.<br />

9 V) on the servo amplifier (see section "Commissioning and start-up procedure"). For each axisspecific<br />

rapid traverse there is an analog voltage which is stored in the machine parameter MP1050.<br />

The resulting lag error sa thus depends on the analog voltage.<br />

U[V]<br />

10<br />

8<br />

6<br />

4<br />

2<br />

2 4 6 8 10<br />

8/95 <strong>TNC</strong> <strong>360</strong> 3 Servo Positioning of the NC Axes 4-55<br />

12<br />

kv = 1, Rapid traverse 10 m/min<br />

12<br />

s a [mm]<br />

A special feed rate for manual operation (<strong>Manual</strong> feed) is stored in machine parameter MP1020. In<br />

general, it is significantly lower than the rapid traverse. Unlike the rapid traverse, this has no effect<br />

on the servo behavior.