11 PLC inputs/outputs<br />

The HEIDENHAIN contouring control <strong>TNC</strong> <strong>360</strong> C has a capacity of max. 119 PLC inputs and 62 PLC<br />

outputs.<br />

55 PLC inputs and 31 PLC outputs can be connected directly to the logic unit. One PLC I/O board<br />

(model PL 410 B or PL 410), with 64 PLC inputs and 31 PLC outputs, can be connected to the logic<br />

unit.<br />

11.1 <strong>Technical</strong> data<br />

PLC inputs<br />

Logic unit/ PL 410 PL 410 B PL 400<br />

Potential range<br />

”1” signal: Ui 13 V to 30.2 V 13 V to 30.2 V 16.5 V to 30 V<br />

”0” signal: Ui<br />

Current range<br />

–20 V to 3.2 V –20 V to 3.2 V –20 V to 4 V<br />

”1” signal: Ii 3.8 mA to 8.9 mA 2.5 mA to 6 mA 6.2 mA to12.6 mA<br />

”0” signal: Ii 1.0 mA at Ui = 3.2 V 0.65 mA at Ui = 3.2 V 1.6 mA at Ui = 4 V<br />

PLC outputs<br />

Transistor outputs with current limiting<br />

Logic unit PL 410 B/ PL 410 / PL 400<br />

Min. output potential<br />

for ”1” signal 3 V below supply voltage<br />

Nominal operating<br />

current per output 0.1 A 1.2 A<br />

Permissible load: resistive load, inductive load only with a quenching diode parallel to the inductance.<br />

No more that half of the outputs may be switched on at simultaneously.<br />

It is not permissible to short-circuit several outputs from the logic unit simultaneously.<br />

A single short circuit does not cause an overload.<br />

3-40 <strong>TNC</strong> <strong>360</strong> 11 PLC inputs/outputs 8/95