1.2.2 Erase PLC program<br />

In the operating mode ERASE PLC PROGRAM, a PLC program contained in the RAM can be deleted<br />

by pressing ENT.<br />

1.2.3 Transfer program from EPROM<br />

In the operating mode TRANSFER PROGRAM FROM EPROM, a program that is stored in the<br />

EPROM can be copied into the RAM by pressing ENT (see also MP 4010).<br />

1.2.4 Translate PLC program<br />

A PLC program created with the PLC editor and stored in RAM must first be compiled in the<br />

TRANSLATE PLC PROGRAM mode before it can be tested.<br />

Press ENT to start translation.<br />

If a PLC program is already in the RAM prior to <strong>TNC</strong> switch-on, it is automatically translated.<br />

Errors in the program can be found during the translation run (see Section "Program creation", "Error<br />

messages").<br />

1.2.5 Utilization<br />

In the UTILIZATION mode of operation the occupied PLC processing time and the vacant PLC<br />

memory are displayed.<br />

The vacant memory is derived from the total memory and the occupied memory.<br />

The vacant PLC memory is displayed in bytes or in percent of the maximum memory (28 KB).<br />

100 % processing time corresponds to 2.5 ms (from 24 ms PLC cycle time). The maximum possible<br />

processing time is determined by the manufacturer and equals 5 ms. The current processing time<br />

indicates the duration of the last PLC scan. If the current processing time exceeds 5 ms, the blinking<br />

error message<br />

will appear.<br />

ERROR IN PLC PROGRAM 53<br />

Please note that the processing time increases by 20% during active V.24 data transfer, and by 5%<br />

during handwheel operation. A PLC program should therefore be tested during active V.24 and<br />

handwheel operation in order to ensure that it will never exceed maximum processing time.<br />