After entry of the code number 531 210, the markers M1000 to M2000 and Bytes B0 to B127 and<br />

the machine parameters are erased.<br />

B0 to B127 Freely available, not deleted with RESET<br />

B128 to B255 Freely available, deleted with RESET<br />

B256 to B511 Data transfer NC → PLC<br />

B512 to B767 Data transfer PLC → NC<br />

B768 to B1023 Machine parameters → PLC<br />

2.3 Data transfer PLC → NC and NC → PLC<br />

PLC → NC<br />

The Q parameters Q100 to Q107 transfer numbers from the PLC to the part program. This means<br />

that Q100 to Q107 can be overwritten by the PLC. The numerical value is registered in Doubleword<br />

D528 and the Q parameter numbers 0 to 7 are defined in Word W516. The numbers 0 to 7<br />

correspond to parameters Q100 to Q107. The transfer is activated with the strobe marker M2713.<br />

The Q parameter values are transferred with the next M/S/T strobe.<br />

Marker Function Set Reset<br />

M2713 Activate the transfer of the value from D528<br />

to the Q Parameter defined in W516<br />

Address Function<br />

PLC NC<br />

D 528 Doubleword with multiple function, here data for transfer from the<br />

PLC to the NC<br />

W516 Q Parameter No. for numerical transfer from PLC to NC<br />

(0 – 7 = Q100 – Q107)<br />

NC → PLC<br />

Sixty different machine parameters are reserved for data transfer in the PLC. These machine<br />

parameters are kept in the Doublewords D768 to D956 and the Words W960 to W968 and W976 to<br />

W988. For example, PLC positioning, datum shifts, feed rates for PLC positioning or coding for the<br />

release of certain PLC functions can be filed in these machine parameters. These numerical values<br />

are evaluated in the PLC program.<br />

Address Function<br />

D768 Value from MP4210.0<br />

D772 Value from MP4210.1<br />

D776 Value from MP4210.2<br />

D780 Value from MP4210.3<br />

D784 Value from MP4210.4<br />

D788 Value from MP4210.5<br />

8/95 <strong>TNC</strong> <strong>360</strong> 2 Program Creation 7-15