5 Encoders<br />

The HEIDENHAIN contouring controls are designed for the installation of incremental linear and<br />

angular encoders.<br />

The control controls the actual position with a measuring step of 0.001 mm or 0.001°. Encoders with<br />

a graduation period of 0.001 mm or 0.001° to 1 mm or 1° may be used.<br />

It does not matter whether the encoder or encoder has one or several reference marks.<br />

However, HEIDENHAIN recommends the use of encoders with distance-coded reference marks,<br />

since the traversing distance when homing on the reference marks is thereby reduced to a<br />

minimum. See chapter "Machine Integration."<br />

5.1 Linear encoders<br />

Measurement of length is best performed by a linear encoder. Insofar as it is compatible with the<br />

accuracy requirements, linear measurement can also be made using a rotary encoder on the<br />

ballscrew.<br />

HEIDENHAIN recommends use of the following linear encoders:<br />

LS 103 C, LS 106 C, LS 405 C, LS 406 C, LS 706 C, LB 326, ULS 300 C.<br />

For linear measurement with the aid of a rotary encoder and a ballscrew you could use, for example,<br />

an ROD 450.<br />

5.2 Angle encoders<br />

For direct angular measurement in the A, B or C axes the following incremental angle encoders are<br />

available: ROD 250 C, ROD 700 C, RON 255 C, and RON 705 C.<br />

In order to meet accuracy requirements, HEIDENHAIN recommends line counts of at least 18 000.<br />

8/95 <strong>TNC</strong> <strong>360</strong> 5 Encoders 3-19