2 <strong>TNC</strong> data interfaces<br />

2.1 General<br />

The <strong>TNC</strong> <strong>360</strong> has a data interface, the RS-232-C/V.24. The HEIDENHAIN FE 401 floppy disk unit, ME<br />

101 magnetic tape unit and external devices with appropriate data interfaces (computers, printers,<br />

readers, punches) can be connected via the RS-232-C/V.24 interface.<br />

Two transmission protocols are available for data transfer:<br />

– Standard data transmission protocol<br />

– Data transfer with Block Check Character (BCC)<br />

The data format and control characters concerned are freely configurable within the framework of<br />

this protocol.<br />

2.2 RS-232-C/V.24 interface<br />

RS-232-C is the designation of a serial interface based on the EIA standard of the same name and is<br />

usable for transmission rates up to 19 200 bits/sec. Data transfer is executed asynchronously, with a<br />

start bit before each character and one or two stop bits after each character. The interface is<br />

designed for transmission distances of up to 20 meters.<br />

The RS-232-C interface has been adopted with slight modifications and has been introduced into<br />

Europe as the V.24 interface. The relevant German standard is DIN 66020.<br />

2.2.1 Hardware<br />

The physical connection between two RS-232-C/V.24 interfaces is an asymmetrical line, i.e. the<br />

common ground connection between transmitter and receiver is used as a return wire.<br />

Physical connections:<br />

TxD<br />

Sender<br />

Transmitter<br />

Übertragungsstrecke<br />

Transmission path<br />

Empfänger<br />

Receiver<br />

RxD TxD<br />

8-10 <strong>TNC</strong> <strong>360</strong> 2 <strong>TNC</strong> data interfaces 8/95<br />

RxD