Machine Function and input Reaction / Page<br />

parameter<br />

CN 123<br />

MP5020 Operating mode EXT: interface configuration<br />

Input range: 0 to 255<br />

CN 123 8-28<br />

Bit 0 7 or 8 Data bits<br />

+0 = 7 Data bits<br />

+1 = 8 Data bits<br />

Bit 1 Block Check Character<br />

+0 = BCC character optional<br />

+2 = BCC character not control character<br />

Bit 2 Transmission stop through RTS<br />

+0 = not active<br />

+4 = active<br />

Bit 3 Transmission stop through DC3<br />

+0 = not active<br />

+8 = active<br />

Bit 4 Character parity<br />

+0 = even<br />

+16 = odd<br />

Bit 5 Character parity<br />

+0 = not required<br />

+32 = required<br />

Bit 6/7 Stop bits<br />

Bit 6 Bit 7<br />

+0 = 1½ Stop bits 0 0<br />

+64 = 2 Stop bits 1 0<br />

+128 = 1 stop bit 0 1<br />

+192 = 1 stop bit 1 1<br />

Bit 8 RTS in quiescent state low<br />

Bit 9 No EOT after ETX received<br />

MP5030.0 Operating mode EXT: data transmission protocol<br />

Input: 0 or 1<br />

0 = "Standard data transmission"<br />

1 = "Blockwise transfer"<br />

MP5040 Data transfer rate for PLC interface<br />

Input range: 0 to 9<br />

0 = 110 baud 5 = 2 400 baud<br />

1 = 150 baud 6 = 4 800 baud<br />

2 = 300 baud 7 = 9 600 baud<br />

3 = 600 baud 8 = 19 200 baud<br />

4 = 1200 baud 9 = 38 400 baud<br />

CN 123 8-28<br />

CN 123 8-42<br />

4/96 <strong>TNC</strong> <strong>360</strong> 3 List of Machine Parameters 5-15