3.12.7 End of Module, Program End (EM) EM<br />

Abbreviation for PLC Editor: EM (END OF MODULE)<br />

Execution time [µs] 2.0<br />

Number of bytes 4<br />

Operands: none<br />

Operation:<br />

Every program and/or every subprogram (Module) is terminated with an EM command. An EM<br />

command in a Module initiates the return jump to the Call Module (CM, CMT, CMF). The program is<br />

continued with the instruction following the Call Module. The command EM is handled as program<br />

end criterion; thus subsequent program instructions can be reached using a jump address.<br />

3.12.8 Jump Label (LBL) LBL<br />

Abbreviation for PLC Editor: LBL (LABEL)<br />

Execution time [µs] 0<br />

Number of bytes 0<br />

Operands: 0 to 511<br />

Operation:<br />

The jump label defines a program position as an entry point for the CM and JP commands. Jump<br />

labels may be allocated addresses in the range 0 to 511.<br />