Machine Function and input Reaction / Page<br />

parameter<br />

CN 123<br />

MP7215 Contouring control or point-to-point and straight-cut<br />

control<br />

Input range 0 to 3<br />

0 = Contouring control (<strong>TNC</strong> <strong>360</strong>)<br />

1 = Point-to-point and straight cut (<strong>TNC</strong> 335)<br />

2 = Position display inhibited, otherwise same as 1<br />

CN 123 4-246<br />

MP7220 Block number step size for ISO programs<br />

Input range: 0 to 255<br />

CN 123 4-132<br />

MP7222 Programming language selection: dialog or ISO<br />

Input: 0 to 2<br />

0 = Selection via MOD<br />

1 = Only dialog<br />

2 = Only ISO<br />

CN 123 4-132<br />

MP7225 Generating blocks with the "ACTUAL POSITION<br />

CAPTURE" key (not in ISO programming)<br />

Input: 0 to 3<br />

0 = no block generation possible<br />

1 = block generation with the "ACTUAL POSITION<br />

CAPTURE" key<br />

2 = block generation with M2829<br />

4-121<br />

MP7230 Switching the dialogue language<br />

Input: 0 or 1<br />

0 = First dialog language<br />

1 = Basic language (English)<br />

CN 123 4-134<br />

MP7235 Resetting the timing<br />

Input: 0 to 4<br />

0 = No resetting<br />

1 = Reset switch-on duration<br />

2 = Reset run time of automatic operation<br />

4 = Reset run time of spindle<br />

4-118<br />

MP7240 Inhibit program input for [Program name] = [OEM<br />

cycle number in EPROM].<br />

Input: 0 or 1<br />

9-5<br />

0 = Inhibited<br />

1 = Not inhibited<br />

MP7245.0 Inhibit the HEIDENHAIN cycles 1 to 15<br />

Input range: 0 to 65 534<br />

MP7245.1 Inhibit the HEIDENHAIN standard cycles<br />

16 to 30<br />

Input range: 0 to 65 535<br />

MP7250 Difference between Q parameter number for "CALLactive"<br />

and "DEF-active" block in OEM cycles<br />

Input 0 to 50<br />

MP7251 Number of global Q parameters that can be<br />

transferred from OEM cycle to the calling program<br />

Input: 0 to 100<br />

4-126<br />

4-127<br />

5-18 <strong>TNC</strong> <strong>360</strong> 3 List of Machine Parameters 4/96<br />

9-5<br />

9-5