Procedure for Optimizing Machine Parameters<br />

Increment MP6230<br />

(e.g. by 10 mm/min)<br />

no<br />

[1] Keep a note of the maximum<br />

feedrate that is possible in the<br />

worst axis.<br />

[2] If the override potentiometers<br />

are already at 150% and the axis<br />

still moves with a steady speed,<br />

increase MP6210.<br />

[2] The optimizing sequence is geared<br />

to the worst axis. This is why the<br />

feedrate must not be further increased<br />

with the override potentiometer and<br />

normal feedrate (MP6230).<br />

Connect a storage oscilloscope to the nominal<br />

command input of the servo amplifier for the<br />

X axis.<br />

In the<br />

"PROGRAM RUN/FULL SEQUENCE"<br />

mode, select optimization program and operate<br />

the external START KEY.<br />

Machine runs, digitizing starts.<br />

Increase the feedrate [1] with the override potentiometer<br />

[2] until X nominal command attains.<br />

maximum value and shows only minor voltage<br />

dips (axis should just still traverse at even<br />

speed).<br />

U[V]<br />

Umax<br />

Are oscillations in<br />

normal direction visible<br />

(stylus tip is seen to lift off<br />

workpiece surface)?<br />

Decrement MP6230 again<br />

(e.g. by 10 mm/min)<br />

Repeat optimizing sequence for Y axis.<br />

Switch the NC program to scanning<br />

direction Y [3].<br />

8/95 <strong>TNC</strong> <strong>360</strong> 9 Touch Probe 4-163<br />

yes<br />

t[s]<br />

Repeat optimizing sequence for Z axis.<br />

Change the scanning range accordingly [3].<br />

Pay particular attention to vertical face.