11.2.2 PLC output<br />

The PLC outputs O0 to O30 and the "Control is operational" output are on connector X21 (PLC<br />

output). The PLC outputs O0 to O7 are also to be found on the connector for the machine control<br />

panel (X27).<br />

See also Section "Machine control panel".<br />

X21 PLC output<br />

D-sub connector (37-pin female insert)<br />

Pin Number Assignment<br />

1 O0<br />

2 O1<br />

3 O2<br />

4 O3<br />

5 O4<br />

6 O5<br />

7 O6<br />

8 O7<br />

9 O8<br />

10 O9<br />

11 O10<br />

12 O11<br />

13 O12<br />

14 O13<br />

15 O14<br />

16 O15<br />

17 O16<br />

18 O17<br />

19 O18<br />

20 O19<br />

21 O20<br />

22 O21<br />

23 O22<br />

24 O23<br />

25 O24 1)<br />

26 O25 1)<br />

27 O26 1)<br />

28 O27 1)<br />

29 O28 1)<br />

30 O29 1)<br />

31 O30 1)<br />

32 Do not use<br />

33 0 V (PLC) 1)<br />

34 Control operational<br />

Housing Outer screen<br />

1) Cannot be switched off via EMERGENCY STOP<br />