6.3.9 Generating NC blocks with the actual-position-capture key<br />

MP7225 was introduced to permit automatic generation of NC blocks in the "Programming and<br />

editing" mode of operation. In plain language dialog (not in ISO programming), the actual-positioncapture<br />

key can generate a positioning block with up to 3 axes, without feed rate, radius<br />

compensation or M functions. This positioning block is inserted behind the block currently selected<br />

in the "Programming and editing" mode. The actual positions are transferred to memory as nominal<br />

position values. The axis is selected with the dialog "AXIS SELECTION" in the MOD mode of<br />

operation. Here up to 3 of 4 axes can be selected by pressing the desired axis keys.<br />

The PLC marker M2829 can also generate a block. The marker is reset by the NC.<br />

MP 7225 Generating blocks with the "ACTUAL POSITION CAPTURE" key<br />

Input: 0 to 3<br />

0 = no block generation possible<br />

1 = block generation with the "ACTUAL POSITION CAPTURE" key<br />

2 = block generation with M2829<br />

Set Reset<br />

M2829 NC block generation PLC NC<br />

6.4 PLC text window<br />

The PLC can display a text above the status line for the circle center. The text length is 16<br />

characters or 32 small characters.<br />

Word W602 causes the text to be displayed.<br />

W 602 A text is displayed in the PLC text window<br />

Bit 0 to 7: Number of PLC error text/dialog<br />

(0 to 199)<br />

Bit 8 to 11: 0000 = Erase display<br />

0001 = Normal display<br />

1111= Inverse display<br />

Bit 12 to 13: 00 = Erase display<br />

01 = Display with small characters<br />

10 = Display with normal characters<br />

Bit 14 to 15: reserved<br />

The text display for PLC Trace (PCTR) was placed up next to * for “Control in operation“ if the actual<br />

value display is small.<br />

6.5 Error messages<br />

Under certain conditions error messages from the NC or the PLC will be displayed on the screen<br />

under the display for the operating mode. Non-flashing error messages can be canceled with the CE<br />

key. In the event of a flashing error message the machine must be switched off and the fault<br />

corrected. If a non-flashing error message is displayed on the screen, marker M2190 will be set.<br />

The machine tool builder determines the conditions under which the PLC will produce error<br />

messages. Up to 100 different PLC error messages can be generated.<br />