Possible errors:<br />

− The transferred axis does not exist.<br />

− The transferred axis was not declared through MP10 and MP60 to be an auxiliary axis.<br />

− The axis is already being positioned.<br />

Call:<br />

PS B/W/D/K (0.to.3 for X/Y/Z/4)<br />

PS B/W/D/K (mm/min)<br />

PS B/W/D/K Bit 0 = 1: negative traverse direction<br />

= 0: positive traverse direction<br />

CM9123<br />

PL B/W/D <br />

0: Positioning was started<br />

1: The transferred axis does not exist<br />

2: The axis is not declared as an auxiliary axis<br />

3: The axis was already positioned<br />

Error status after call: M3171 = 0: Positioning was started<br />

= 1: Faulty execution<br />

4.9.10 Module 9124 Override for PLC axis<br />

An override value can be entered to influence the traversing speed of a PLC axis.<br />

Constraints:<br />

− The entered axis must have been activated through MP10 and declared as auxiliary axis through<br />

MP60.<br />

− The override value can lie between 0% and 100.00% (resolution 0.01%) and must be transferred<br />

as an integer (0 ... 10 000).<br />

− When movement starts, the last transferred override value is considered.<br />

− After a reset or after an interruption of the PLC program the override value in each PLC axis is<br />

set to 100.00%.<br />

− It is also possible to call the module while a PLC axis is moving.<br />

− The module can be called in the same PLC scan in addition to a module from the group<br />

(9120/9121/9123). It does not become effective, however, until the previously called module is<br />

finished.<br />

Possible errors:<br />

- The transferred axis does not exist.<br />

- The transferred axis was not declared through MP10 and MP60 to be an auxiliary axis.<br />

- The transferred override value is incorrect.<br />

8/95 <strong>TNC</strong> <strong>360</strong> 4 PLC Modules 7-117