6.10 Programming station<br />

Machine parameters can be used to set the control so that it can be utilized without a machine tool<br />

as a programming station, without the machine. In this setting only the operating modes<br />

"Programming and editing" and "Test run" function. It is possible to select whether the PLC should be<br />

active or not in the "programming station" setting.<br />

MP7210 Programming station<br />

Input values: 0 to 2<br />

6.11 Dialog language<br />

Entry: 0 = Control and programming<br />

1 = Programming station, "PLC active"<br />

2 = Programming station, "PLC inactive"<br />

The HEIDENHAIN contouring controls are available in ten different dialog languages, see chapter<br />

"Introduction." The dialog language can be altered by a simple software exchange. English, as a<br />

basic language, is stored in every control as a second language and can be selected by machine<br />

parameter.<br />

If the basic language English has been selected, then marker M2041 is set by the NC.<br />

MP7230 Switching the dialog language<br />

Entry: 0 or 1<br />

0 = First dialog language<br />

1 = Basic language - English<br />

Marker Function Set Reset<br />

M 2041 Basic language - English is selected NC NC<br />

6.12 Decimal sign<br />

The decimal sign can be selected by machine parameter.<br />

MP7280 Decimal sign<br />

Entry: 0 or 1<br />

0 = Decimal comma<br />

1 = Decimal point<br />

4-134 <strong>TNC</strong> <strong>360</strong> 6 Display and Operation 8/95