4.4.3 Rigid tapping<br />

Tapping without a floating tap holder is defined in the NC program by "CYCL DEF 17 RIGID<br />

TAPPING" and called by CYCL CALL . Here too the dynamic behavior is determined by machine<br />

parameters.<br />

Before tapping, the axes (e.g. Z and S) are synchronized by a spindle orientation, i.e. each Z position<br />

is assigned to a particular spindle position. This means, that the same thread can be cut more than<br />

once. The fixed assignment of the spindle position depends on the thread pitch which is entered in<br />

the cycle. Because of the fixed thread pitch the correlated Z-dependent spindle position can not be<br />

altered by the operator. The thread pitch can be positive or negative.<br />

Marker M2095 is set at the start of the cycle. With this marker the PLC program can switch on the<br />

spindle, if required, with M03 or M04. The marker M2499 (Close control loop - S-axis) must be set to<br />

zero in acknowledgment. Only then can the orientation take place, and spindle and tool axis move<br />

synchronously until the cycle has been completely processed. Before orientation the NC outputs an<br />

M05. An acknowledgment is necessary.<br />

After this, marker M2095 is reset by the NC and the control loop is opened. The spindle position is<br />

displayed during tapping. The ramps for the drilling process are stored in MP3410.3.<br />

F<br />

0<br />

S<br />

0<br />

M05<br />

Acknowledge-<br />

Rückmeldung<br />

ment M-Funktion of<br />

M function<br />

M2095<br />

M2499<br />

Cycle Zyklusstart<br />

Start<br />

orientierter Oriented stop Halt<br />

Positioning Positionierfenster window<br />

reached erreicht (MP7150)<br />

Ramp Rampe from aus<br />

MP3410.3<br />

Oriented orientierter stop Halt<br />

End Zyklus of cycle<br />

Ende<br />

8/95 <strong>TNC</strong> <strong>360</strong> 4 Spindle 4-103