4.9.3 Module 9102: Interface status<br />

Module 9102 reports all relevant status information about the data interfaces in bit-encoded form.<br />

The "Interface ready" information is not updated until the interface is assigned to either the PLC or<br />

the NC. If the interface is not assigned, the module reports the status that was valid prior to the last<br />

interface enable.<br />

Module call:<br />

PS K/B/W/D Interface 0 = RS-232-C/V.24<br />

(1 = RS-422/V.11)<br />

CM 9102<br />

PL B/W/D The status of the interface is bit-encoded and filed into the addressed storage area<br />

from the STACK.<br />

The following states are possible:<br />

Bit 0 = 1The interface is assigned to the NC.<br />

Bit 1 = 1The interface is assigned to the PLC.<br />

Bit 2 = 1The interface is ready.<br />

Bit 3 = 1The transmitting buffer is empty.<br />

Bit 4 = 1A transmit error has occurred.<br />

Bit 5 = 1The receiving buffer is full.<br />

Bit 6 = 1A receive error has occurred.<br />

Bit 7 = 1 The character for end of text ( or defined in MP5201.2) was received, i.e.<br />

the interface is no longer ready to receive.<br />

All higher-order bits in the STACK are deleted, combinations are possible.<br />

Marker M3171 is set if the call parameters of the module are outside the permitted range.<br />