MP1810 Kv factor for operation with lag<br />

Input range 0.1 to 10 [1/min]<br />

MP1810.0 kv factor X axis<br />

MP1810.1 kv factor Y axis<br />

MP1810.2 kv factor Z axis<br />

MP1810.3 kv factor 4th axis<br />

MP1010 Rapid traverse<br />

Input range 80 to 300 000 [mm/min]<br />

MP1010.0 Rapid traverse X axis<br />

MP1010.1 Rapid traverse Y axis<br />

MP1010.2 Rapid traverse Z axis<br />

MP1010.3 Rapid traverse 4th axis<br />

MP1050 Analog voltage for rapid traverse<br />

Input range 4.5 to 9 [V]<br />

MP1050.0 Analog voltage X axis<br />

MP1050.1 Analog voltage Y axis<br />

MP1050.2 Analog voltage Z axis<br />

MP1050.3 Analog voltage 4th axis<br />

MP1020 <strong>Manual</strong> feed<br />

Input range 80 to 300 000 [mm/min]<br />

MP1020.0 <strong>Manual</strong> feed X axis<br />

MP1020.1 <strong>Manual</strong> feed Y axis<br />

MP1020.2 <strong>Manual</strong> feed Z axis<br />

MP1020.3 <strong>Manual</strong> feed 4th axis<br />

Address Function<br />

D596 Rapid traverse from PLC<br />

Servo accuracy:<br />

The internal servo accuracy of the control is always 1 µm. The control has, however, a display step<br />

of 5 µm or 1 µm, selectable by machine parameter MP7290. The rounding up or down is only in the<br />

display (see section "Display and operation").<br />

Normally a servo accuracy of 1 µm is sufficient, i.e. the control must be able to generate at least one<br />

voltage step per 1 µm positional deviation.<br />

4-56 <strong>TNC</strong> <strong>360</strong> 3 Servo Positioning of the NC Axes 8/95