1.3 Test functions for the PLC program<br />

1.3.1 TRACE function<br />

The TRACE function makes it possible to check the logical states of the markers, inputs, outputs,<br />

timers and counters.<br />

If this function is selected, the following menu appears:<br />

SELECT I/O/C/T/M<br />

DISPLAY TRACE BUFFER<br />

START TRACE<br />

END TRACE<br />

SELECT I/O/C/T/M<br />

Those inputs (I), outputs (O), counters (C), timers (T) or markers (M) whose logical states are to be<br />

checked can be entered into a table in the SELECT I/O/C/T/M function. A maximum of 16 markers,<br />

timers etc. can be simultaneously verified. Each position is interrogated via dialogue. Erroneous<br />

entries can be deleted by pressing DEL.<br />

The memory for the trace mode (TRACE BUFFER) has space for 1024 individual states per operand,<br />

i.e. 1024 PLC processes are recorded. In order to record the required time duration of the user, a<br />

TRIGGER condition can be entered for each operand:<br />

"1" = Recording when operand is logically "1"<br />

"0" = Recording when operand is logically "0"<br />

If the trigger position is verified with the NOENT key, it means that a trigger condition is not<br />

required. 512 states are recorded before and after a trigger event. The trigger event is regarded as<br />

fulfilled only when the conditions for all operands are simultaneously fulfilled with TRIGGER.<br />

Example: M2064 1<br />

M2065 0<br />

M2066 1<br />

I5<br />

Trigger event: M2064 logical "1"<br />

M2065 logical "0"<br />

M2066 logical "1"<br />

The state of I5 has no significance for the trigger event: it is, however, recorded.<br />

If no trigger condition is entered for the operands, the states of the operands are continually<br />

recorded and, after ending the trace mode, the last 1024 states are displayed.<br />

To exit the SELECT I/O/C/T/M function, press END.<br />

8/95 <strong>TNC</strong> <strong>360</strong> 1 PLC Functions 7-9