Machine Function and input Reaction/<br />

parameter<br />

CN 123<br />

MP32 Checking the edge separation of the measuring<br />

system signals<br />

Input range: 0 to 31<br />

Bit 0 X axis +0 = not active<br />

+1 = active<br />

Bit 1 Y axis +0 = not active<br />

+2 = active<br />

Bit 2 Z axis +0 = not active<br />

+4 = active<br />

Bit 3 4th axis +0 = not active<br />

+8 = active<br />

Bit 4 S axis +0 = not active<br />

+16 = active<br />

MP40 VDU display<br />

Input range: 1 to 15<br />

Bit 0 X axis +0 = not active<br />

+1 = active<br />

Bit 1 Y axis +0 = not active<br />

+2 = active<br />

Bit 2 Z axis +0 = not active<br />

+4 = active<br />

Bit 3 4th axis +0 = not active<br />

+8 = active<br />

MP50 Controlled axes<br />

Input range: 0 to 15<br />

Bit 0 X axis +0 = not controlled<br />

+1 = controlled<br />

Bit 1 Y axis +0 = not controlled<br />

+2 = controlled<br />

Bit 2 Z axis +0 = not controlled<br />

+4 = controlled<br />

Bit 3 4th axis +0 = not controlled<br />

+8 = controlled<br />

MP60 PLC axes<br />

Input: 0 to 15<br />

Bit 0 Axis X +0 = normal NC axis<br />

+1 = PLC axis<br />

Bit 1 Axis Y +0 = normal NC axis<br />

+2 = PLC axis<br />

Bit 2 Axis Z +0 = normal NC axis<br />

+4 = PLC axis<br />

Bit 3 4th axis +0 = normal NC axis<br />

+8 = PLC axis<br />

Page<br />

4/96 <strong>TNC</strong> <strong>360</strong> 3 List of Machine Parameters 5-5<br />