6.3.4 Display of M functions<br />

The miscellaneous functions for control of the spindle (M03, M04, M05) and the coolant (M08, M09)<br />

are displayed in the status display. The display of these M functions is controlled by the PLC, i.e. the<br />

machine tool builder must take this into account when creating the PLC program. The markers<br />

M2485 and M2486 also change the polarity of the analog voltage for the spindle. M2608 switches<br />

off the analog output for the spindle. The programmed spindle speed is, however, still displayed (see<br />

section "Spindle").<br />

Marker Function Set Reset<br />

M2485 Status display and sign of S analog for M03 PLC PLC<br />

M2486 Status display and sign of S analog for M04<br />

M2487 Status display for M05 and spindle stop<br />

M2508 Status display M08 or M09<br />

0 = Status display M09<br />

1 = Status display M08<br />

M2608 Status display M03, M04, M05 inverse and<br />

S analog output = 0V<br />

M2609 Status display M08, M09 inverse<br />

6.3.5 Display of run duration<br />

The <strong>TNC</strong> has three timers that measure the duration in seconds of the following states:<br />

– Control (dialog "Control on")<br />

– Program run (dialog "Program run")<br />

– Spindle (dialog "Spindle on")<br />

Control on<br />

This timer starts with the first PLC run after the control reset.<br />

Program run<br />

This timer measures the duration of program run (see User's <strong>Manual</strong> <strong>TNC</strong> <strong>360</strong>).<br />

Spindle<br />

The spindle operating time starts when the Markers M2485/M2486 are set and stops when they are<br />

reset.<br />

Display of run duration<br />

The three timers can be called by entering the code number 85 7282 (see User's <strong>Manual</strong> <strong>TNC</strong> <strong>360</strong>)<br />

and can then be reset, depending on MP 7235.<br />

Resetting the run duration timers<br />

All timers are kept in the battery-buffered RAM and are reset after the error message "Operation<br />

parameters erased."<br />

8/95 <strong>TNC</strong> <strong>360</strong> 6 Display and Operation 4-117