Machine<br />

parameter<br />

MP4230.0<br />

to<br />

MP4230.31<br />

to<br />

MP4239.0<br />

to<br />

MP4239.31<br />

MP4310.0<br />

to<br />

MP4310.6<br />

Function and input Reaction /<br />

CN 123<br />

Set a number in the PLC via module 9032<br />

Input value: -30 000 000 to + 30 000 000<br />

Set a number in the PLC, in the Word range W976<br />

to W988<br />

Input range: 0 to 65 535<br />

3.7 Setting the data interfaces<br />

Page<br />

5-14 <strong>TNC</strong> <strong>360</strong> 3 List of Machine Parameters 4/96<br />

7-17<br />

7-17<br />

Machine Function and input Reaction / Page<br />

parameter<br />

CN 123<br />

MP5010.0 Control characters for "blockwise transfer"<br />

Input range: 0 to 32 382<br />

Character for program end and beginning<br />

The character for program end also applies for<br />

"Standard data interface"<br />

CN 123 8-26<br />

MP5010.1 ASCII characters for data input CN 123 8-27<br />

MP5010.2 ASCII characters for data output CN 123 8-27<br />

MP5010.3 ASCII characters for beginning and end of the<br />

command block<br />

CN 123 8-26<br />

MP5010.4 ASCII characters for positive acknowledgment or<br />

negative acknowledgment<br />

CN 123 8-26<br />

MP5010.5 ASCII character for data transmission ended CN 123 8-26