3.11.4 Load word accumulator onto the data stack (PSW) PSW<br />

Abbreviation for PLC Editor: PSW (PUSH WORDACCU)<br />

Execution time [µs] 3.4<br />

Number of bytes 20<br />

Operands: none<br />

Operation:<br />

The content of the Word Accumulator can be buffered with the PSW command. For this purpose,<br />

the Word Accumulator is copied into the Data Stack. The content of the Word Accumulator (32 bit)<br />

reserves two Words on the Data Stack. In the event of a stack overflow, an error message will be<br />

issued.<br />

3.11.5 Acquire logic accumulator from the data stack (PLL) PLL<br />

Abbreviation for PLC Editor: PLL (PULL LOGICACCU)<br />

Execution time [µs] 2.2<br />

Number of bytes 16<br />

Operands: none<br />

Operation:<br />

The PLL command complements the PSL command. With a PLL instruction, bit 7 from the current<br />

address of the Data Stack is copied into the Logic Accumulator. If the stack is empty, an error<br />

message will be issued.<br />

3.11.6 Acquire word accumulator from the data stack (PLW)<br />

Abbreviation for PLC Editor: PLW (PULL WORDACCU)<br />

Execution time [µs] 2.6<br />

Number of bytes 16<br />

Operands: none<br />

Operation:<br />

The PLW command complements the PSW command. With a PLW instruction, two Words are<br />

copied from the Data Stack into the Word Accumulator. If the stack is empty, an error message will<br />

be issued.<br />