Examples for the commands PS, PL, PSL, PSW, PLL, PLW<br />

The Module 15 is to be called at a specific point in the program. After the return into the main<br />

program, the original Accumulator content is again required for further program run.<br />

Accumulator contents prior to the Call Module: 1A 44 3E 18<br />

Line Instruction Accumulator Contents<br />

49<br />

.<br />

.<br />

.<br />

50 PSW<br />

52 CM 15<br />

54 PLW<br />

55 .<br />

.<br />

.<br />

1 A 4 4 3 E 1 8<br />

1 A 4 4 3 E 1 8 8<br />

1 A 4 4 3 E 1 8<br />

Data stack:<br />

1 A 4 4<br />

3 E 1 8<br />

Line 50: Save the Word Accumulator onto the Data Stack.<br />

Line 52: Subprogram 15 is called up.<br />

Line 54: The original Accumulator contents are transferred back from the Data Stack and<br />

is available for further program run.<br />

Note:<br />

The sequence for stack operations is the same for all commands. Only the data width varies.<br />

7-92 <strong>TNC</strong> <strong>360</strong> 3 Commands 8/95