06.08.2013 Views

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

The orange axis keys can be used to select a different fault-related axis for the X axis. After pressing<br />

the GOTO key, the axis keys can be used to select a correction table for one of the other axes. The<br />

correction value which is entered must not exceed the maximum correction-value difference. The<br />

correction-value difference is calculated as follows:<br />

Max. correction-value difference =<br />

distance between correction points [mm]<br />

64<br />

In our example, the result is<br />

16.384 mm<br />

64<br />

= 0.256 mm<br />

Only the compensation points of the error curve should be entered. The control will automatically<br />

make a linear interpolation between the compensation points. In the example above the correction<br />

table is thus:<br />

Y = F(Z)<br />

DATUM POINT –990<br />

SETUP 14<br />

0 Z–990 Y+0<br />

1 Z–973.616 Y–0.06<br />

2 Z–957.232 Y–0.09<br />

3 Z–940.848<br />

4 Z–924.464<br />

5 Z–908.08 Y–0.12<br />

6 Z–891.696 Y–0.12<br />

7 Z–875.312 Y–0.1<br />

8 Z–858.928 Y–0.09<br />

.<br />

.<br />

.<br />

No entry is necessary in lines 3 and 4 (press the NO ENT key), because there is no visible kink. The<br />

individual lines of the correction table are selected either by the arrow keys or with the GOTO key.<br />

Press the END key to leave the correction table.<br />

Special case: Axis of rotation<br />

In a correction table for a rotary axis, the entered distance between correction points must be large<br />

enough that the 64 correction points will cover a complete revolution of <strong>360</strong>°. An angular separation<br />

of at least 5.625° (2 16 ) is therefore necessary. For an axis of rotation, correction values will only be<br />

recognized for entries from 0 to <strong>360</strong>°.<br />

Input and output of the correction table via the data interface<br />

After entering the code number 105296 the correction table can be entered or read out via the data<br />

interface.<br />

As usual, the data transfer is initiated with the EXT key. The correction table receives the file name<br />

extension ".S".<br />

4-26 <strong>TNC</strong> <strong>360</strong> 1 Machine Axes 8/95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!