11.5 PL 410 B / PL 410 PLC I/O unit<br />

The PL 410 B / PL 410 has 64 PLC inputs, 31 PLC outputs and one "control-is-operational" output.<br />

In its interface to the LE and its load capacity of inputs and outputs it is identical to the PL 400.<br />

The analog inputs (X15 to X22) of the PL 410 cannot be evaluated in the LE <strong>360</strong> C! The DIL switch<br />

on the PCB of the PL 410 must therefore be set to OFF (as is stated on the housing). The PLC<br />

outputs are powered in groups and are therefore switched off via EMERGENCY STOP in groups.<br />

Connecting cable<br />

PL 410B<br />

PL 410<br />

X1<br />

Id.-Nr. 263 662 ..<br />

max. 20 m<br />

8/95 <strong>TNC</strong> <strong>360</strong> 11 PLC inputs/outputs 3-49<br />