16.3.8 Optimizing the integral factor<br />

MP7290: "0" (display step = 1 µm)<br />

Machine stands in position, under servo control.<br />

↓<br />

MP1080 integral factor (for X axis):<br />

raise entry value 1) , until the<br />

Servo positioning becomes noticeably unstable<br />

(observe the actual value display).<br />

↓<br />

MP1080: reduce the entry value in small steps<br />

until the servo positioning is steady again 2).<br />

↓<br />

Repeat adjustment for Y axis, Z, and IV.<br />

Whether or not an integral factor is possible in connection with the automatic offset adjustment with<br />

MP 1220 can only be judged when observing the complete machine.<br />

The optimum solution must be found during the commissioning procedure.<br />

1) First entry value 100, raise subsequent values in steps of 100.<br />

2) For drives which are not quite free of backlash the entry value should be "0".<br />

4-242 <strong>TNC</strong> <strong>360</strong> 16 Commissioning and Start-up Procedure 8/95