11.4.2 PLC inputs/outputs on the PL 400<br />

The PLC inputs/outputs on the PL 400 are distributed among nine connectors.<br />

Assignments as follows:<br />

X1 X2<br />

Pin Number Assignment<br />

Pin Number Assignment<br />

PL 400<br />

PL 400<br />

1 O32 1 O43<br />

2 O33 2 O44<br />

3 O34 3 O45<br />

4 O35 4 O46<br />

5 O36 5 O47<br />

6 O37 6 O48<br />

7 O38 7 O49<br />

8 O39 8 O50<br />

9 O40 9 O51<br />

10 O41 10 O52<br />

11 O42 11 O53<br />

12 Do not use 12 Do not use<br />

X3 X4<br />

Pin Number Assignment<br />

Pin Number Assignment<br />

PL 400<br />

PL 400<br />

1 O54 1 I126<br />

2 O55 2 I74<br />

3 O562) 3 I73<br />

4 O572) 4 I72<br />

5 O58 5 I71<br />

6 O592) 6 I70<br />

7 O602) 7 I69<br />

8 O612) 8 I68<br />

9 O622) 9 I67<br />

10 Control is operational 10 I66<br />

11 Do not use 11 I65<br />

12 +24 V cannot be switched<br />

off via ext. EMERGENCY<br />

OFF1) 12 I64<br />

1) +24 V must always be connected, even if the outputs are not used.<br />

2) Outputs cannot be switched off via EMERGENCY STOP<br />