06.08.2013 Views

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

Technical Manual TNC 360 - heidenhain - DR. JOHANNES ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

HR<br />

HR 330<br />

HR 330.001 max. 6 m<br />

HR 330 max. 2.2 m<br />

Id.-Nr. 251 534 ..<br />

EMERGENCY OFF<br />

max. 24V<br />

BLUE<br />

BLUE<br />

GREEN<br />

YELLOW<br />

BROWN<br />

WHITE<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

2<br />

1<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

• • •<br />

Adapter<br />

HR 330<br />

BLUE<br />

BLUE<br />

max. 48 m<br />

Id.-Nr. 249 889 ..<br />

WHITE<br />

BROWN<br />

YELLOW<br />

GREEN<br />

•<br />

max. 50 m<br />

Id.-Nr. 249 814 ..<br />

3-34 <strong>TNC</strong> <strong>360</strong> 10 Handwheel Input 8/95<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

•<br />

max. 49 m<br />

WHITE<br />

BROWN<br />

YELLOW<br />

GREEN<br />

•<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

LE<br />

X11<br />

The adapter includes a cable with a 9-pin connector for the logic unit, and two terminals for<br />

connecting the 24 V of the EMERGENCY STOP control circuit (max. load 1.2 A).<br />

See also section "Mounting dimensions".<br />

10.3 Integral handwheel HR 130<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

Electronic<br />

handwheel<br />

0V<br />

+12V ± 0.6V(U V)<br />

The HR 130 is the integral version of the HR 330, without the keys for the axes, rapid traverse etc.<br />

It may be attached directly to the logic unit, or via an extension cable (Id.-Nr. 249 814 ..).<br />

DTR<br />

RXD<br />

The HR 130 (Id.-Nr. 254 040 ..) is available in several versions (standard cable length 1 m):<br />

– Small knob; axial cable exit: version 01<br />

– Small knob; radial cable exit: version 02<br />

– Large knob; axial cable exit: version 03<br />

– Large knob; radial cable exit: version 04<br />

– Ergonomic knob; radial cable exit: version 05<br />

Mounting dimension drawings are provided at the end of this chapter.