LE - Power supply<br />

VDE 0551<br />

1<br />

Selectable<br />

connection<br />

3<br />

+24V<br />

0V<br />

+24V<br />

0V<br />

Emergency stop<br />

controlled<br />

PLC - Power supply<br />

VDE 0160<br />

basic insulation<br />

+24V<br />

X31 1<br />

0V<br />

2<br />

X23 1<br />

X9<br />

2<br />

X14<br />

X13<br />

X12<br />

X11<br />

X10<br />

Emergency Stop<br />

X8<br />

SI<br />

0V<br />

X7<br />

8 x 1,2A<br />

+5V<br />

Insulated<br />

0V<br />

stab. supply<br />

voltages<br />

Power supply<br />

X7<br />

8 x 1,2A<br />

Optoc.<br />

X8<br />

8 x 1,2A<br />

X8<br />

7 x 1,2A<br />

LE <strong>360</strong><br />

X3-X6<br />

64 Inputs<br />

1<br />

2<br />

X1 X2 X3 X4<br />

Unit PL 410B<br />

X1 X26<br />

X2<br />

6mm 2<br />

6mm 2<br />

6mm 2<br />

B<br />

1<br />

0<br />

Machine Encoders<br />

3<br />

SI<br />

X24/1<br />

SI<br />

X24/2<br />

+24V- +24V-<br />

4<br />

X24/3<br />

0V<br />

6<br />

X6 X12<br />

X21 X21 X21 X21 X22<br />

7x0,1A<br />

Emergency Stop<br />

0,1A<br />

2<br />

6mm<br />

6mm<br />

2<br />

6mm<br />

2<br />

2<br />

6mm<br />

2<br />

6mm<br />

Triggering<br />

touch probe<br />

Optoc.<br />

C X25<br />

8/95 <strong>TNC</strong> <strong>360</strong> 15 Grounding Diagram 3-75<br />

16x0,1A<br />

8x0,1A<br />

32 Inputs<br />

C<br />

V<br />

C<br />

C<br />

Optoc.<br />

Test point 1<br />

(Fault voltg. 0V/<br />

housing)<br />

L C<br />

C<br />

B<br />

X11<br />

X9<br />

X23<br />

X27<br />

X8<br />

8 x24 Matrix<br />

8 x 0,1A<br />

1,2,3,4<br />

(Spindel)<br />

Spindel<br />

V<br />

Test point 2<br />

(Fault voltg.with grounded nominal<br />

value input)<br />

Operating panel<br />

Adapter<br />

V.24<br />

Handwheel<br />

Display<br />

Unit<br />

Keyboard<br />

Unit<br />

24 Inputs Machine<br />

Op. Panel<br />

Terminal box<br />

Analog<br />

input<br />

To prevent earth circuits,<br />

the measuring voltages should not be grounded.<br />

If it must be grounded,<br />

ensure that the line is short and noise immune.<br />

A grounded nominal input<br />

results in anearth circuit.<br />

Therefore ensure that the 0V<br />

and ground line are short and noise immune<br />

*)<br />

2<br />

4mm<br />

Measuring voltage<br />

0V<br />

15 Grounding Diagram<br />

0V<br />

0V<br />

1-Axis<br />

2-Axis<br />

3-Axis<br />

4-Axis<br />

(Spindle)<br />

Motor control<br />

with nominal value<br />

difference input<br />

Spindle<br />

Motor control<br />

without nominal<br />

value difference<br />

input