8 Touch Probe System Input<br />

The 3D touch probe systems from HEIDENHAIN can be delivered in two versions:<br />

– TS 120 with cable transmission and integrated APE interface electronics<br />

– TS 511 with infrared transmission of the trigger signal and connectable via APE interface<br />

electronics<br />

For start-up and adjustment of the 3D touch probe systems see Chapter "Machine Integration".<br />

8.1 Connector assignment X12<br />

X12 Touch probe system TS 120/TS 511<br />

Flange socket with female connector insert (15-pin)<br />

Pin Number Signal designation<br />

1 Inner screen (0 V)<br />

3 Ready/standby<br />

4 Start<br />

5 +15 V ± 10 % (UP)<br />

6 + 5 V ± 5 % (UP)<br />

7 Battery warning<br />

8 0 V (UN)<br />

9 Trigger signal<br />

10<br />

Trigger signal 2<br />

2, 11 to 15 Do not use<br />

2 Stylus in rest position = signal high<br />

3-28 <strong>TNC</strong> <strong>360</strong> 8 Touch Probe System Input 8/95