U [V]<br />

t [ms]<br />

If the K v factor is too large, the system will oscillate about the pre-controlled speed set value.<br />

The size of the K v factor is normally the same as the K v factor for operation with servo lag<br />

Depending on the dynamic characteristics of the machine it may also be higher (see section<br />

"Commissioning and start-up procedure").<br />

MP1530 Damping factor for transient response<br />

Input value: 0.01 to 0.999<br />

MP1520 Position approach speed<br />

Input value: 0.1 to 10 [m/min]<br />

MP1510 K v factor for feed forward control<br />

Input value: 0.1 to 10 [1/min]<br />

MP1510.0 K v factor X axis<br />

MP1510.1 K v factor Y axis<br />

MP1510.2 K v factor Z axis<br />

MP1510.3 K v factor 4th axis<br />