Manufacturer Applications<br />

Variable Service Reset<br />

For some models post 2000 MY, variable service reset should be used. To reset the<br />

service interval, enter 00000 into service reset channel 2 to clear the service<br />

counters.<br />

The channels 40, 41, 42, 43, 44 and 45 are used on installing a new instrument pack.<br />

Old values are entered into the new instrument pack to ensure that vehicle servicing<br />

is carried out at the correct intervals.<br />

Service Type Adaption<br />

Channel<br />

Counter Contents Adaption Value to<br />

Reset<br />

Service 2 Reset service counters<br />

(distance and time)<br />

00000*<br />

40 Distance travelled since<br />

last service in 100s of km<br />

00000<br />

41 Time elapsed since last<br />

service in days<br />

00000<br />

42 Lower limit for distance to<br />

next inspection<br />

-----<br />

43 Upper limit for distance to<br />

next inspection<br />

-----<br />

44 Upper limit for time to<br />

next inspection<br />

-----<br />

45 Quality of engine oil -----<br />

NOTE: * This value must be entered manually. Other adaption channels will<br />

automatically reset.<br />

Login to ECM (VAG Mode11)<br />

Some ECMs may require a valid login code to be entered before allowing some<br />

actions such as re-coding, adaptation values, coding cruise control, A/C etc.<br />

Each vehicle control module has a unique login code that is stored in the 'Vehicle<br />

Factory Repair Manual' or can be obtained from a VAG dealer. The login code is a 5<br />

digit number between 0 and 65535 and is entered via the OmiCheck. If the login is<br />

accepted 'Code Accepted' is displayed, if, however, the login code is incorrect the<br />

response depends upon the protocol:<br />

• KeyWord 1281 - Communication between the OmiCheck and the module will be<br />

broken and the message 'Datalink error, Login lost - Please check the code<br />

entered then retry' (the control module will need to be reset by switching the<br />

ignition off and then on again).<br />

• KeyWord 2000 & CAN - an error message is displayed and communications are<br />

maintained<br />