Manufacturer Applications<br />

Transmitters/Key Programmers<br />

This option allows the user to program/re-program remote keys/fobs for use with the<br />

vehicle security/central locking.<br />

Synchronise ECU<br />

This option allows the user to setup a new/replacement ECU with the vehicles<br />

existing ECUs.<br />

Write Cal Values<br />

This option enables the user to re-calibrate the suspension on Range Rover vehicles<br />

fitted with Air Suspension.<br />

Air Suspension System (Ride Level Module - RLM)<br />

• Discovery III (L319) (2005 - 2009)<br />

• Range Rover Sport (L320) (2005 - 2009)<br />

• Range Rover (L322) (2006 - 2009)<br />

There are several functions available via the OmiCheck.<br />

• Set <strong>Operating</strong> Mode.<br />

• Set Tolerance Control Mode.<br />

• Deflation Routines.<br />

Set <strong>Operating</strong> Mode<br />

This procedure is used to set the RLM to different modes. Modes can be set under<br />

the ‘Configuration’ option of the OmiCheck. The current operating mode can be<br />

displayed under the ‘Live Data’ option of the OmiCheck.<br />

Pre-test conditions<br />

• The ignition must be ON.<br />

• An approved battery charger must be connected to ensure consistent power<br />

supply.<br />

Normal Mode<br />

This is the normal operating mode for the RLM.<br />