6.2.2.1 Fixed heading<br />

Do not use fixed heading for vessels! Use fixed heading only for<br />

fixed installations like remote areas or oil rigs, during training and<br />

test.<br />

You can enable fixed heading and enter the fixed heading in<br />

degrees. Click Apply.<br />

Note<br />

If you change the heading settings you must make an azimuth<br />

calibration afterwards.<br />

6.2.2.2 Azimuth calibration<br />

Azimuth calibration is done toward a satellite of a known position.<br />

After finding the satellite, the system can calculate the azimuth<br />

offset of the ADU installation. The satellite and transponder<br />

properties for the calibration can be selected from a list of reference<br />

satellites or supplied manually.The calibration has 2 steps: Azimuth<br />

calibration and cable calibration.<br />

There are 2 ways to make an azimuth calibration:<br />

• Using a service profile.<br />

• Using user defined input on the calibration page.<br />

To make an azimuth calibration with a service profile, do as follows<br />

Calibration of the SAILOR 900 VSAT<br />

6666<br />

1. Click SERVICE > Calibration.<br />

2. Select the service profile in the drop down list, see Preparing for<br />

calibration on page 6-4. All profiles with the VSAT modem <strong>Service</strong><br />

& Calibration are displayed in the list.<br />

Configuration<br />

Important<br />

Do not refresh the browser window during<br />

calibration, this will interrupt and restart the<br />

calibration procedure. The screen is not<br />

automatically updated when new data are<br />

available from the SAILOR 900 VSAT.<br />

You may click the button Refresh in the web<br />

interface to update the screen.<br />

3. Click Start in the section Azimuth calibration and wait typically 5<br />

minutes for the calibration to finish. After finished calibration<br />

click the button Refresh. A message is displayed when the<br />

calibration has been completed.<br />

4. Click Start below Cable calibration and wait typically 10 minutes<br />

for the calibration to finish. A message is displayed when the<br />

calibration has been completed successfully.<br />

98-133966-E2 Chapter 6: Configuration 6-7